AEMO Connectivity
Related feature: AEMO Connectivity
Connectivity to marketnet requires three high level things:
- The complete list of FRMPs across all brands that the Data Holder is responsible for
- A mTLS certificate
- A set of two usernames and passwords that can access all FRMPs that the Data Holder is responsible for
info
We require two sets of credentials to enable automatic regular password rotation (marketnet requires rotation every 90 days) without downtime to the Data Sharing.
| Configuration | Data Type | Description |
|---|---|---|
| frmps | list of strings | The complete list of FRMPs that are in use across the brands for retrieving AEMO data |
| mtlsCertificate | string | The MTLS certificate for the marketnet connection |
| username1 | string | The username for the first set of credentials |
| password1 | 🔒 secure string | The password for the first set of credentials |
| username2 | string | The username for the second set of credentials |
| password2 | 🔒 secure string | The password for the second set of credentials |
info
See here for setup runsheet.