Skip to main content

REGISTER-OFFLINE

NameVerify that a Data Holder continues to function as per normal when Register is broken
Category

REGISTER

Execution Method

SEMI AUTOMATED (VTT)

DescriptionThis test case validates that Data Holders continue to operate when the Register is offline.
Preconditions
Steps
  1. Using a valid token for an arrangement and a valid CA signed certificate verify the GET /banking/accounts call is functional
  2. Suspend access to the Register via network means (firewall drop etc)
  3. Wait 1 hour
  4. Verify that (1) is still functional for a Recipient including retrieving a new Access Token using an existing Refresh Token
  5. Wait 1 hour
  6. Verify that (1) is still functional for a Recipient including retrieving a new Access Token using an existing Refresh Token
Inputs
  • Dynamic Client Software Statement
  • Token from valid arrangement
Expected ResultsThe Holder continues to operate with existing Recipient statuses even if the Register goes offline for an extended period of time